NL +31 24 648 86 88 NL  
BE +32 3 309 32 09 BE  
photonics@gotoPEO.com
en
  • Nederlands
  • English
  • Français
Photonics
Products
  • Light Measurement Solutions
  • Distance & Position Detectors
  • Photodiodes & Advanced Photodiodes
  • Spectrometers
  • Light Meters
  • Goniometers
  • Integrating Spheres
  • Calibration Services
  • Software
  • Position Sensitive Detectors (PSDs)
  • SEEPOS Measurement System
  • Electron & Ion Sensors
  • Silicone Photodiodes
Start R&D process
Partners
News and Events
Vacancies
Contact
Products/Light Measurement Solutions/Integrating Spheres/

GL OPTI SPHERE 205

Any questions or would you like to order this product? Do not hesitate to contact us

Contact

Product categories

Filter the products and categories by showing only certain partners.

Partners
All

Centronic EO
GL Optic
On-Trak
SiTek
Clear filters
  • Light Measurement Solutions
    • Spectrometers8
    • Light Meters11
    • Goniometers3
    • Integrating Spheres8
    • Calibration Services2
    • Software5
  • Distance & Position Detectors
    • Position Sensitive Detectors (PSDs)15
    • SEEPOS Measurement System5
    • Electron & Ion Sensors1
  • Photodiodes & Advanced Photodiodes
    • Silicone Photodiodes11

Luminous flux & radiant power measurements of LEDs

An automated, user-friendly substitute for determining the luminous flux and radiant power of LEDs and other small light sources is the GL OPTI SPHERE 205 small integrating sphere. Every measurement complies with the CIE Technical Committee’s suggestions, as stated in the CIE 127:2007 Technical Report.
The GL OPTI SPHERE’s clever design makes it possible to attach various adapters and measure a variety of light sources. Measurements of front-emitting diodes in 2π geometry at the wall entrance are compliant with CIE standards. It is recommended to test other kinds of LEDs using 4π geometry at the sphere’s center. Set up the system according to your application’s specifications.

Flexible and expandable

Select from a variety of spectrometers, measure in 2π or 4π, and employ SMA fiber optics or direct connections. These are but a handful of the possible hardware choices. Make even more use of your expertise by utilizing any of our strong software analysis and automation solutions.

Fast and accurate

The GL OPTI SPHERE 205, which is meant to be an everyday tool, is a fantastic substitute for external labs or outdated equipment. On your desk, in your lab, or on the assembly line, get instantaneous laboratory-level color and radiometric accuracy.

Simplicity in design

With just a button push, users of the GL OPTI SPHERE can access all light attributes thanks to its integrated system design. Give up on complicated software and hardware and take charge of your optical development instead.

GL OPTI SPHERE 205 Usage

Simplified luminous flux

In order to make light measuring for individual LEDs and small LED modules easier, GL OPTI SPHERE 205 was created. Conventional systems are difficult to operate, frequently sensitive to slight physical changes, and include confusing software that makes it hard to get reliable results without the user’s intervention. Peripheral integration makes automated sequences possible, which eliminates this problem.

Reliable measurement of light

Barium sulfate (BaSO4) on the interior walls of the sphere ensures high reflectance qualities of up to 97%. With the appropriate adapter placed either directly on the sphere or via a SMA fiber-optic cable, any GL SPECTIS series spectrometer can be used with any GL Optic sphere.

GL OPTI SPHERE 205 Features

Precisely designed aperture

The port of the sphere is equipped with a precisely designed 50mm aperture which can be used in partial flux measurements of LEDs. For this application, the test LED is installed outside the sphere at a defined distance and the flux is measured inside the sphere.

CIE compliant

Measurement of LEDs compliant with CIE 127:2007 and new CIE S 025/E:2015. This sphere also complies with other global standards and all American IES LM and European EN requirements for professional LED light measurement instrumentation.

Useful accessories

There are attachments available that are appropriate for certain measuring needs. An additional light source is included in the GL OPTI SPHERE 205 to offset the test LED’s self-absorption effect.

Automated self-absorbance correction

The GL SPECTROSOFT software fully controls the integrated LED auxiliary light source to provide prompt corrections and the best outcomes.

GL OPTI SPHERE 205 Metrics

Integrated quantities

  • Total luminous flux [ lm ]
  • Radiant power [ W/nm ]
  • Total photon flux
  • PBAR and more.

Colorimetric quantities

  • Correlated color temperature – CCT and Duv
  • Color rendering indices – Ra, CRI, R1 to R14, TM-30
  • Fidelity index Rf
  • MacAdam elypses.
  • Binning
  • Color coordinates

Optional quantities*

  • Luminous Efficacy [lm/w]
  • Power Factor

PDF and available downloads

You can download the information on this page and the available downloads as one PDF file. There are 2 downloads available for this product.

Enter your email address once to gain access to all downloads on the PEO website.

    Download Technical Datasheet Download Catalogue

    There are 2 downloads available for this product.

    Download Technical Datasheet
    Download Catalogue
    Contact
    NL +31 24 648 86 88
    BE +32 3 309 32 09
    photonics@gotoPEO.com
    Havenweg 16, 6603 AS Wijchen
    Leonardo da Vincilaan 19A/8, 1831 Diegem
    Go to the contact page
    ISO 9001
    Call-back request

      Your information





      Privacy policy
      PEO B.V. © 2025 All Rights Reserved

      Go to gotopeo.com

      Products
      • Light Measurement Solutions
      • Distance & Position Detectors
      • Photodiodes & Advanced Photodiodes
      • Spectrometers
      • Light Meters
      • Goniometers
      • Integrating Spheres
      • Calibration Services
      • Software
      • Position Sensitive Detectors (PSDs)
      • SEEPOS Measurement System
      • Electron & Ion Sensors
      • Silicone Photodiodes
      Start R&D process
      Partners
      News and Events
      Vacancies
      Contact

      English
      • Nederlands
      • English
      • Français

      NL +31 24 648 86 88
      BE +32 3 309 32 09
      photonics@gotoPEO.com

      LinkedIn

      Choose your cookie preferences. To provide the best experiences, we use cookies, among other things, to store and/or access device information. By consenting to these cookies we can process certain data on this site. If you do not give permission, this may have a negative effect on the operation.

      Functional Active by default
      The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service expressly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication via an electronic communications network.
      Statistics
      The technical storage or access used solely for statistical purposes.
      Marketing
      The technical storage or access is required to create user profiles to send advertisements, or to track the user on a website or across multiple websites for similar marketing purposes.