NL +31 24 648 86 88 NL  
BE +32 3 309 32 09 BE  
photonics@gotoPEO.com
en
  • Nederlands
  • English
  • Français
Photonics
Products
  • Light Measurement Solutions
  • Distance & Position Detectors
  • Photodiodes & Advanced Photodiodes
  • Spectrometers
  • Light Meters
  • Goniometers
  • Integrating Spheres
  • Calibration Services
  • Software
  • Position Sensitive Detectors (PSDs)
  • SEEPOS Measurement System
  • Electron & Ion Sensors
  • Silicone Photodiodes
Start R&D process
Partners
News and Events
Vacancies
Contact
Products/Light Measurement Solutions/Light Meters/

LUMINANCE / RADIANCE

Any questions or would you like to order this product? Do not hesitate to contact us

Contact

Product categories

Filter the products and categories by showing only certain partners.

Partners
All

Centronic EO
GL Optic
On-Trak
SiTek
Clear filters
  • Light Measurement Solutions
    • Spectrometers8
    • Light Meters11
    • Goniometers3
    • Integrating Spheres8
    • Calibration Services2
    • Software5
  • Distance & Position Detectors
    • Position Sensitive Detectors (PSDs)15
    • SEEPOS Measurement System5
    • Electron & Ion Sensors1
  • Photodiodes & Advanced Photodiodes
    • Silicone Photodiodes11

Optic probes for measuring radiance or irradiance

It is crucial to understand what the client needs to measure, the quantities he must supply, the width of the spectral range he must measure in, and the measuring point diameter he will be comfortable with in order to match the best optical probe to the customer’s needs.
For radiometric measurements, GL Optic provides a range of optical probes. Their spectral range, level of cosine correction, and kind of optic fiber are different.

Ready-set-go

Measurement probes, fiber optic cables, and adapters for specialized spectrometers are all included in each full package. includes calibration that can be linked to national labs.

Smart detection

A sophisticated detection system included in every GL Optic Spectrometer recognizes a new probe and installs the relevant calibration file automatically.

Extended spectral range

These optical probes, which are made of high-transmission quartz fiber optics, have a wide spectral range of 200–1050 nm, from UV to NIR.

 

GL OPTI PROBE 1.0.10 Luminance Usage

The purpose of this accessory is to measure the luminance [cd/m2] of plasma FPDs, flat LCDs, and OLED panels. Television screens, computer monitors, avionics displays, and other electronic displays are frequently examined items. Projection screens, signage, and reflecting surfaces (such as walls and work surfaces) are also frequently measured.
This optical probe detects the light that a specific point on the surface of a comparatively large or extended source emits in a given direction. For measuring distance, the measuring probe can be mounted on a tripod; for measuring contact, it can be mounted directly on a screen using a specific stripe.GL SPECTIS 1.0 or GL SPECTIS 1.0 Touch can be connected via the optic probe. A polymer fiber optic cable is included with the probe. Spectrum that can be used: 400–730 nm.

GL OPTI PROBE 1.0.11 Luminance Usage

This optic probe comes with a flexible fiber optic cable and is shaped like a pen with a measuring point diameter of just 1 mm. When small regions need to be measured, it is extremely helpful. GL SPECTIS 1.0 or GL SPECTIS 1.0 Touch can be connected to via the optic probe.
The purpose of this accessory is to measure the luminance [cd/m2] of plasma FPDs, flat LCD and OLED panels. Avionics, other electronic displays, and signal indicators are common devices to be tested. This optical probe detects the light that a specific location on the surface emits in a certain direction. A polymer fiber optic cable is included with the probe. Spectrum that can be used: 400–730 nm.

GL OPTI PROBE 1.0.12 Luminance Usage

An optical fiber-equipped luminance-measuring telescope guarantees an exactly parallel observation beam. Adaptable to a tripod. Spot diameter at 0.5 m distance is 8 mm. Range of spectra: 400–1050 nm.
Telescopes that measure luminosity make sure that the observation beam is precisely parallel. For measuring other projection displays, LCD, LED, and OLED panels, as well as flat screens. The kit comes with fiber optics, a measuring probe, and an adapter for GL SPECTIS 1.0 spectrometers that has a coder. Tripods can be equipped with probes.

GL OPTI PROBE 5.0.10 Luminance Usage

Luminance probe for point measurement of projection displays, indication lights, LCD, LED, and OLED panels. The kit comes with a counterweight with a strap to hang above the measured screen, quartz fiber optics, an adapter with a coder for the GL SPECTIS 1.0 series spectrometer, and a measuring probe.
The probe’s frame is prepared to hold a typical photo tripod. Within the range of the utilized spectrometer, this probe covers the entire spectral range, from UV to IR. N.A. is 0.20.

GL OPTI PROBE 5.0.51 Luminance Usage

For point measurement of flat screens, LCDs, LED OLED panels, projection displays, and signaling lights, use a pen-style brightness probe. The kit comes with a quartz fiber optic adapter, a measuring probe, and a coder for spectrometers that are GL SPECTIS 5.0, 6.0, and 8.0 compatible. Within the range of the utilized spectrometer, this probe covers the entire spectral range, from UV to IR. N.A. is 0.20.

PDF and available downloads

You can download the information on this page and the available downloads as one PDF file. There is one download available for this product.

Enter your email address once to gain access to all downloads on the PEO website.

    Download Technical Datasheet

    There is one download available for this product.

    Download Technical Datasheet
    Contact
    NL +31 24 648 86 88
    BE +32 3 309 32 09
    photonics@gotoPEO.com
    Havenweg 16, 6603 AS Wijchen
    Leonardo da Vincilaan 19A/8, 1831 Diegem
    Go to the contact page
    ISO 9001
    Call-back request

      Your information





      Privacy policy
      PEO B.V. © 2025 All Rights Reserved

      Go to gotopeo.com

      Products
      • Light Measurement Solutions
      • Distance & Position Detectors
      • Photodiodes & Advanced Photodiodes
      • Spectrometers
      • Light Meters
      • Goniometers
      • Integrating Spheres
      • Calibration Services
      • Software
      • Position Sensitive Detectors (PSDs)
      • SEEPOS Measurement System
      • Electron & Ion Sensors
      • Silicone Photodiodes
      Start R&D process
      Partners
      News and Events
      Vacancies
      Contact

      English
      • Nederlands
      • English
      • Français

      NL +31 24 648 86 88
      BE +32 3 309 32 09
      photonics@gotoPEO.com

      LinkedIn

      Choose your cookie preferences. To provide the best experiences, we use cookies, among other things, to store and/or access device information. By consenting to these cookies we can process certain data on this site. If you do not give permission, this may have a negative effect on the operation.

      Functional Active by default
      The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service expressly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication via an electronic communications network.
      Statistics
      The technical storage or access used solely for statistical purposes.
      Marketing
      The technical storage or access is required to create user profiles to send advertisements, or to track the user on a website or across multiple websites for similar marketing purposes.